Informed when the air gets bad

Email notifications monitor an AirWatch and send an email to any recipients when the PM10 value exceeds the threshold: to the shift supervisor, the safety officer, maintenance, or an external service provider.

Setup

Create in two steps

  1. 1

    Choose AirWatch and recipients

    Enter any email addresses or add members of the site with one click.

  2. 2

    Set the threshold

    With the smart threshold recommendation: it analyzes the air quality of the last 24 hours, 7 or 30 days, optionally only during working hours, shows the history with the recommended and the current threshold, and proposes a suitable value that you apply with one click.

Screenshot: Smart threshold recommendation with historyScreenshot to follow

The recommendation detects workday patterns, for example “Air quality is better on weekends”.

No notification spam

Hysteresis: report once, not every minute

Values that fluctuate around the threshold would trigger new emails constantly without a countermeasure. An automatic hysteresis prevents that: only when the value has dropped clearly below the threshold and exceeds it again is another email sent.

The notification card shows the live value, threshold, hysteresis, recipients, and whether the value is currently above or below the threshold. A master switch disables the notification temporarily.

Screenshot: Notification card with threshold, hysteresis, and recipientsScreenshot to follow

Email

What the email contains

  • Template in German or English

    With device name and current value. Subject and text can be adjusted and reset to the default.

  • Typical recipients

    Shift supervisor, safety officer, maintenance, external service provider.

Good to know

Notifications are sent by email and refer to the PM10 threshold of an AirWatch. For errors, warnings, service due dates, or the connection status of a unit, use the service page and the error messages on the dashboard.

The hysteresis is value-based: what matters is how far the value drops below the threshold, not for how long.

Terms explained briefly

Hysteresis
Distance between the value that triggers a notification and the value at which the notification is considered ended. Prevents fluctuations around the threshold from generating repeated notifications.
Threshold
PM10 value in µg/m³ at which the email is sent. The recommendation derives it from the values measured over the last days.