Off after the shift, on before the shift starts
A schedule switches one or more filter units on or off at a fixed time on selected weekdays. Operation only during production hours, without anyone having to remember.
What schedules do
One action, one time, selected weekdays
Every schedule performs exactly one action: switch on or switch off. A daily rhythm therefore consists of two schedules, for example “Morning start” at 07:00 switch on and “Evening shutdown” at 18:00 switch off. The time refers to the local time zone.
Every schedule is a card with action, time, days, and devices. A master switch disables it temporarily without deleting it, for example during maintenance. Settings can be changed at any time.
Setup
Create in two steps
- 1
Name and devices
Assign a name, with quick picks: Morning start, Evening shutdown, Lunch break off, Night mode, Weekend plan, Shift change. Then select the devices.
- 2
Time, days, action
Set the time, choose the weekdays (quick picks “Mon–Fri” or “All days”), and define the action “Switch on” or “Switch off”.
Typical applications
What schedules are made for
Only during production hours
Units run when work is being done. That saves energy without anyone having to switch.
Pre-filtering before the shift starts
The hall is already ventilated when work begins.
Shutdown after the shift
No running overnight when nobody is there anymore.
Shift patterns
Different times per weekday, for example shorter Fridays.
Devices
All remotely controllable units
Connected natively
AirDome, CleanAirTower (self-cleaning), and CleanAirTower SF 9000.
Through the KEMPER Connect Bridge
VacuFil Compact, MaxiFil Clean, Automation Line, AirDome, and CleanAirTower. Bridge machines appear under their machine name.
Through the KEMPER Connect IoT Kit
PLC-controlled filter units such as WeldFil, VacuFil 2000/4000, or KemJet, also under their machine name.
Difference from the Rule Engine
Schedules switch regardless of air quality. If you want to combine time frames and air quality control, use the time windows within a Rule Engine rule (minimum operation, quiet hours, fixed value), because there the automation knows both settings and resolves conflicts according to fixed rules.
Standalone schedules and the Rule Engine should not control the same unit.
Good to know
A schedule has one action (on or off), not a start and end time. There are no exceptions for individual days; instead, a schedule can be disabled temporarily. The time zone is that of the browser when the schedule is created.