Monitoring · Indoor Climate
Is mold looming, is it too warm?
The KEMPER Connect Climate Sensor measures temperature and relative humidity in the workroom every 15 minutes. KEMPER Connect rates both according to ASR A3.5, the German workplace rule for indoor temperature, and estimates the mold risk before it becomes visible.

Rating
According to the workplace rule, not by feel
Temperature and humidity appear as a colored display with a rating according to ASR A3.5: Cold, Cool, Slightly cool, Comfortable, Warm, Hot, Critical, and Too dry, Dry, Comfortable, Humid, Too humid respectively.
Notices appear below the ASR minimum temperature, at “measures recommended” from 26 °C, at “measures required” from 30 °C, and when the humidity leaves the comfort band of 40 to 60 %. If the temperature is below 20 °C, KEMPER Connect states in plain language from which work intensity it is still sufficient under ASR A3.5.

Ranges
What applies when
The ranges KEMPER Connect uses to rate temperature and humidity, and the notice the dashboard shows for each.
| Measurement | Rating | Range | Notice in the dashboard |
|---|---|---|---|
| Temperature | Cold | below 12 °C | Below the ASR minimum temperature |
| Temperature | Cool | 12 to 17 °C | Below the ASR minimum temperature, depending on work intensity |
| Temperature | Slightly cool | 17 to 20 °C | Below the ASR minimum temperature, depending on work intensity |
| Temperature | Comfortable | 20 to 26 °C | – |
| Temperature | Warm | 26 to 30 °C | Measures recommended |
| Temperature | Hot | 30 to 35 °C | Measures required |
| Temperature | Critical | 35 °C and above | Measures required |
| Humidity | Too dry | below 30 % | Outside the comfort band |
| Humidity | Dry | 30 to 40 % | Outside the comfort band |
| Humidity | Comfortable | 40 to 60 % | – |
| Humidity | Humid | 60 to 70 % | Outside the comfort band |
| Humidity | Too humid | above 70 % | Outside the comfort band |
The minimum temperature under ASR A3.5 depends on work intensity: from 20 °C for light seated work down to 12 °C for heavy work. The dashboard states in plain language from which work intensity the current value is sufficient.
Mold risk
Mold risk: detect it before it becomes visible
The mold risk is shown in four levels from Low to High, with safety margin, mold limit, and dew point. The basis is the 80 % criterion from DIN 4108-2 and EN ISO 13788.
The display is explicitly marked as an estimate from the room air. On the site page, a mold risk panel shows the room most at risk; the device dashboard shows the value per sensor, together with the thresholds, battery level, and radio signal.

Exceedances
How long was it too warm or too humid?
For the last 24 hours, the exceedance analysis shows for each threshold how long the value was outside: above 26 °C, above 30 °C, and outside the humidity comfort band, each with duration, share, and number of readings.
The climate history below shows temperature and humidity with the ASR zones in the background. The history covers day and week, with comparison to the previous period, statistics, and time distribution.

Site page
All climate sensors on three tabs
Overview
Two scales for temperature and humidity with site average and spread, mold risk panel, rankings “Warmest” and “Coldest Locations”, and an ASR A3.5 explanation with the minimum temperatures per work intensity.
History
Day or week, comparison with the previous period, statistics, and time distribution by temperature and humidity range. The climate history shows the ASR zones.
Devices
Temperature, humidity, mold risk with safety margin, battery, and signal per sensor.
Monitoring kits
The right kit
The KEMPER Connect Climate Sensor comes as a kit with a gateway, optionally together with the Noise Sensor. Place the gateway, add the sensors, done.
Climate Monitoring Kit
Document indoor climate according to ASR A3.5 and detect mold risks early.
Included in the kit
- 1 ×KEMPER Connect Gateway with power supply
- 5 ×KEMPER Connect Climate Sensor with batteries and mounting material
- Cellular data for the gateway
What KEMPER Connect shows
- Temperature and humidity, rated according to ASR A3.5
- Mold risk estimate per room in four levels
- Exceedance analysis: time above 26 and 30 °C and outside 40 to 60 % humidity
Noise and Climate Monitoring Kit
Noise and indoor climate through one gateway.
Included in the kit
- 1 ×KEMPER Connect Gateway with power supply
- 5 ×KEMPER Connect Noise Sensor with batteries
- 5 ×KEMPER Connect Climate Sensor with batteries and mounting material
- Cellular data for the gateway
What KEMPER Connect shows
- Everything the Noise and the Climate Monitoring Kit evaluate
- Noise level and indoor climate side by side in the site overview
- One gateway for all ten sensors
In every kit
No setup
Place the gateway, plug in the power supply, add each sensor with its ID and code.
Cellular built in
SIM card in the gateway; Wi-Fi and Ethernet are also possible.
Battery approx. 3 to 5 years
Standard batteries that you replace yourself.
Range approx. 250 to 500 m
LoRaWAN radio inside buildings, one reading every 15 minutes.
Custom kit
More sensors or a different mix? Other combinations are available on request.
Scope
ASR A3.5 (German technical rule for workplaces, room temperature) is the rating basis. The measurements are ambient measurements at the installation point of the sensor.
For the indoor climate there is currently no PDF report, no export, and no working hours filter. Air quality and noise offer all three.
Terms explained briefly
- ASR A3.5
- German technical rule for workplaces on room temperature. Names minimum temperatures per work intensity and measures from 26 and 30 °C respectively.
- Dew point
- Temperature at which the humidity condenses on surfaces. The closer surfaces are to the dew point, the higher the mold risk.
- 80 % criterion
- Rating approach from DIN 4108-2 / EN ISO 13788: from about 80 % relative humidity on a surface, mold can grow.
- Comfort band
- Range of relative humidity from 40 to 60 % in which the indoor climate is considered pleasant.